RAW thermal camera module comparison: 14-bit data and 16-bit containers, editorial illustration
|

RAW Thermal Camera Modules: 7 Essential Checks

A RAW thermal camera can deliver more useful signal detail than a display-ready video stream, but the format label leaves three questions unanswered: does it measure temperature, how many bits contain meaningful data, and how fast does that exact output run? This guide compares three CAMCUDA profiles—radiometric AeroMini 640, radiometric ThermoCore 640 and non-radiometric FlexMini 640—through seven practical integration checks.

It also covers the questions engineers raise once a RAW thermal camera module reaches the bench: the difference between radiometric and non-radiometric output, what Y16, 14-bit and 16-bit mean inside a frame, how to record and convert raw thermal data, how much host bandwidth a 640 × 512 stream needs, and how to write a sample acceptance plan before ordering.

640 × 512 · RAW OUTPUT SELECTION

Choose the data path your host actually needs.

All three use 640 × 512, 12 μm detectors. Their measurement capability, RAW profiles and frame rates serve different requirements.

Open the RAW module selector →
15 HzAeroMini radiometric RAW profile
25–30 HzThermoCore radiometric RAW; configuration dependent
50 HzFlexMini non-radiometric RAW profile

RAW thermal camera module comparison: three distinct profiles

The rates below apply to the RAW profiles discussed here. They should not replace every detector, processed-video or camera-version rate listed for the same family.

ParameterAeroMini 640
60 Hz imaging
ThermoCore 640
Radiometric USB RAW
FlexMini 640
14-bit RAW · Y16
Compared versionRadiometric RAWRadiometric USB RAWNon-radiometric RAW
Detector format640 × 512 · 12 μm640 × 512 · 12 μm640 × 512 · 12 μm
Spectral band8–14 μm LWIR8–14 μm LWIR8–14 μm LWIR
RAW data description14-bit / 16-bit RAW options14-bit / 16-bit RAW options16-bit grayscale samples; effective sensor bit depth unverified on the tested unit
Compared RAW rate15 Hz25–30 Hz; confirm the exact 30 Hz configuration50 Hz
Temperature measurementRadiometric version; matching conversion requiredRadiometric version; matching conversion requiredNot provided by this version
Other published rate contextProduct page lists a 25 Hz radiometric optionCurrent product page and listed UVC formats specify 25 HzKeep the selected RAW source and host format attached to 50 Hz
Host format boundaryObtain the matching RAW interface and SDK definitionUse the matching USB SDK mode; exact packing mattersUSB YUY2/YUYV transport with serial output switching on the tested unit
Product detailsAeroMini 640 configurations →ThermoCore 640 configurations →FlexMini 640 configurations →

For temperature-enabled RAW capture at 15 Hz, start with the AeroMini radiometric profile. For a radiometric requirement around 25 Hz, evaluate ThermoCore; specify 30 Hz explicitly when needed. For non-radiometric processing at 50 Hz, evaluate FlexMini. The interactive selector filters these profiles by measurement requirement and minimum rate, then estimates payload.

How to read this RAW thermal camera table

Every row describes a specific compared version, not the whole product family. A family page can list several camera versions, interface boards and output modes. The RAW profile you integrate is one combination of those choices, and its rate, bit description and conversion rules belong to that combination.

The shared detector format is the easiest row to misread. Three RAW thermal camera modules with the same 640 × 512 array, 12 μm pitch and 8–14 μm band can still deliver different data: one may expose a temperature-capable radiometric path, another a non-radiometric signal path, and each may run its RAW mode at a different frame rate.

What the three profiles have in common

All three are long-wave infrared RAW thermal camera modules with the same array size and pixel pitch. With the same effective focal length and an ideal rectilinear model, these detector dimensions give the same calculated field of view. Actual lens FOV, distortion and image cropping still need their own specifications. A host can share a 640 × 512 image-size setting across the three profiles, while retaining a separate decoder and control configuration for each. It does not mean the decoders, control commands or conversion steps are interchangeable.

Where the profiles differ

  • Measurement: AeroMini and ThermoCore are compared as radiometric versions; FlexMini is compared as a non-radiometric version.
  • Rate: 15 Hz, 25–30 Hz and 50 Hz for the respective RAW profiles, with the 30 Hz ThermoCore configuration requiring confirmation.
  • Data description: AeroMini and ThermoCore offer 14-bit / 16-bit RAW options; FlexMini carries 14-bit data in a 16-bit container.
  • Controls: each family uses its own SDK, and numeric control values do not translate between them.

Radiometric vs non-radiometric thermal camera: what RAW changes

Searchers often treat “radiometric” and “RAW” as synonyms. They describe different properties. Radiometric describes whether a camera configuration, together with its calibration and conversion model, can report temperature estimates. RAW describes where in the processing chain the output is taken and how it is represented. A RAW thermal camera can be radiometric or non-radiometric, and a radiometric camera can also produce ordinary display video.

Two independent questions

The first question is about meaning: do the numbers in the frame have a documented relationship to scene temperature? The second is about form: is the output a high-bit-depth signal before display mapping, or an 8-bit image already compressed for viewing? Treating them as one question is the most common source of mismatched RAW thermal camera purchases.

CombinationWhat the host receivesTypical usesWhat it cannot do on its own
Radiometric + RAWHigh-bit-depth values plus a documented route to temperature through matching calibration and conversionSpot, area and per-pixel temperature estimates; logging data for later re-analysisGuarantee accuracy outside the stated range and conditions, or without correct emissivity and environment settings
Non-radiometric + RAWHigh-bit-depth signal values without a temperature calibrationDetection, tracking, custom contrast mapping, machine-vision input, image fusionReport calibrated temperature
Radiometric + display videoA viewable image; temperatures may be available through a separate SDK pathLive viewing with measurement overlays provided by the camera or software; not a RAW thermal camera pathPreserve the full signal relationship in the video pixels
Non-radiometric + display videoAn AGC-mapped image for viewingObservation, situational awarenessSupport quantitative analysis of pixel values

Why temperature needs more than a frame

An infrared camera senses radiation, not temperature directly. Converting that signal into an object temperature depends on the object’s emissivity, reflected radiation from the surroundings, the distance and atmosphere between camera and object, and any window in the optical path. The FLIR measurement-parameter guide summarises these influences. A radiometric configuration provides calibration and a conversion method; the user still supplies scene parameters that the frame itself cannot contain.

When non-radiometric RAW is the right choice

Many embedded vision systems never need a temperature number. Object detection, people counting, perimeter tracking and image fusion care about contrast and consistency rather than degrees. For those applications a non-radiometric RAW thermal camera keeps more signal detail than 8-bit video and lets the host apply its own contrast mapping. FlexMini 640’s 50 Hz non-radiometric profile is aimed at that kind of processing path.

When you need a radiometric RAW thermal camera

Choose a radiometric version when the output must be expressed in temperature: threshold alarms, process monitoring, inspection reports or data that will be re-analysed later with different emissivity settings. In the compared set, AeroMini 640 and ThermoCore 640 are the radiometric options, with listed thermography ranges of −20°C to +550°C and −20°C to +150°C respectively.

Can non-radiometric RAW data give temperature?

Not as a product capability. Within one frame, relative comparisons require a known processing stage, signal polarity and scaling. Those properties cannot be inferred from a white-hot preview. The relationship between counts and temperature is not characterised as a measurement capability for the compared non-radiometric version and can shift with the camera’s internal temperature and correction state. Any calibration a project builds on top of such data is its own characterisation, outside the product specification.

1. Decide whether the RAW thermal camera must measure temperature

A grayscale number can represent detector signal, a corrected intensity or a defined temperature quantity. The same 16-bit memory slot can hold any of these. Thermography requires the appropriate camera version, calibration and conversion documentation, together with the applicable range and operating conditions.

AeroMini’s radiometric listing gives −20°C to +550°C; ThermoCore’s gives −20°C to +150°C. Those ranges do not establish equal accuracy or interchangeable conversion equations. FlexMini’s compared non-radiometric output supplies grayscale signal data; selecting RAW does not turn it into a calibrated thermometer.

Keep a high-bit-depth capture for the processing or measurement path and create a separate display image when needed. A palette can improve visibility without providing a temperature scale. For a broader explanation of these pipeline choices, Teledyne FLIR’s Lepton video-output guide distinguishes measurement-oriented output from AGC-processed display output. Lepton’s formats and commands are product-specific; they are not CAMCUDA interface specifications.

Questions to answer before choosing a RAW thermal camera

  • Does the application need temperature values, or only consistent signal values?
  • Which temperature range must be covered, and does the listed range of the candidate version include it?
  • Is temperature needed for every pixel, for selected regions, or only for alarms?
  • Where will conversion run: in the RAW thermal camera itself, in a vendor SDK on the host, or in your own code using documented rules?
  • Which scene parameters, such as emissivity and distance, must the operator be able to set?

Counts, temperature planes and conversion

Radiometric products deliver temperature information in different ways. Some send signal counts and leave conversion to an SDK; others provide a separate temperature plane or a temperature-encoded output. Ask which method the chosen RAW thermal camera version uses, which units and scaling apply, and whether the conversion depends on settings that must be written before capture. The answer affects payload, decoder design and how recordings can be re-processed later.

What RAW, Y16, 14-bit and 16-bit mean inside a RAW thermal camera frame

RAW thermal camera datasheets compress several separate facts into short labels. Unpacking them before writing code prevents the most expensive integration mistakes: decoding the wrong bits, mistaking storage width for precision, or treating counts as temperature.

The frame as an array of words

A 640 × 512 frame contains 327,680 pixels. In an unpacked 16-bit layout each pixel occupies one two-byte word, so one image plane is 655,360 bytes. Some interfaces add header lines, telemetry rows or padding at the end of each row; others send telemetry separately. The image plane is what the payload calculations in this guide describe.

Four labels, four meanings

LabelWhat it describesWhat it does not tell you
RAWNumeric image output taken from a vendor-defined processing stage; the precise tap must be namedWhich corrections have already been applied, or whether values are temperatures
Y16A single-channel format storing one 16-bit word per pixelHow many of the 16 bits carry signal, or what the values mean
14-bitThe number of meaningful sample bits: 16,384 possible levelsTemperature resolution, sensitivity or accuracy
16-bitEither a container width or a native sample depth: 65,536 possible codesWhich of the two it is, unless the documentation says so

Container width versus effective precision

Fourteen meaningful bits give 16,384 levels. Placing them in a 16-bit word gives a container that could hold 65,536 codes, but the extra two bits add no signal information. They may be zero, may duplicate other bits, or may be reserved. A host should know which before applying any mask to RAW thermal camera data.

Alignment matters too. In general, a 14-bit value can be stored right-aligned, using the low fourteen bits, or left-aligned, using the high fourteen bits. Either convention is possible in principle; only the vendor’s format description establishes which one a particular RAW thermal camera uses.

How to check a sample frame

  • Find the maximum value across many frames. Values that never exceed 16,383 are consistent with right-aligned 14-bit data.
  • Check whether the lowest two bits are always zero. That pattern would suggest left-aligned data.
  • Plot a histogram. A distribution with regular gaps can reveal a shift or scaling step.
  • Compare a known scene change, such as a hand entering the view, with the numeric response.

These checks support, but do not replace, the documented layout. They are a quick way to catch a RAW thermal camera decoder that produces a plausible picture from wrongly interpreted numbers.

Bit depth is not sensitivity

Bit depth sets how finely the output can be quantised. Thermal sensitivity is specified separately, often as NETD under stated scene, optics and frame-rate conditions. NETD expresses noise relative to a temperature difference; it is not an absolute measurement-accuracy specification or a guaranteed threshold for every scene. A higher RAW thermal camera bit count does not imply better sensitivity, and the two should be compared from their own specifications, not inferred from each other.

2. Separate 14-bit signal precision from a 16-bit container

Fourteen bits represent 16,384 possible levels; sixteen bits represent 65,536 possible codes. A host often stores each pixel in two bytes even when only fourteen bits carry the signal. The wider container simplifies storage and processing, but it does not add measured information.

The current FlexMini manual documents 16-bit grayscale storage with unverified effective sensor precision. AeroMini and ThermoCore offer 14-bit / 16-bit RAW options; confirm the payload for the selected mode.

The Linux V4L2 luma-format documentation also separates storage from sampling precision. Standard Y16 stores a pixel in a little-endian 16-bit word, while a separate big-endian format exists. Do not assume an undocumented vendor stream follows either layout solely because its SDK calls the output “16-bit RAW.”

Choosing between 14-bit and 16-bit RAW options

When a RAW thermal camera offers both 14-bit and 16-bit descriptions, ask what changes between them. The answer may be the sample depth, the processing stage, the packing, or the meaning of the values. Selecting “16-bit” in a menu should be followed by a request for the format definition that applies to that selection, not by an assumption that precision has increased.

3. Identify the processing stage, not just the RAW label

Automatic gain control maps scene values into a useful display range. Disabling that mapping can preserve a different signal relationship for host processing, but it does not establish that every correction, filter or calibration step has been bypassed. NUC and temperature compensation may still operate upstream.

ThermoCore documents AGC levels 0–5, with level 0 disabling AGC. The current FlexMini guide documents a separate serial mode switch. The controls are configuration-specific.

Use the FlexMini 640 user manual V1.2.0 with the matching package. Check the selected source and currently effective source, especially when a stream restart is required. A successful command response alone does not prove the next buffer already contains the requested data.

When quantitative analysis needs data before AGC

AGC is scene-adaptive. It stretches whatever range is present in the current view to fill the output, so the same object can produce different pixel values as the background changes. That is helpful for a viewer, but a fixed threshold on those mapped values can change meaning from frame to frame. A temperature conversion defined for unmapped signal cannot be applied unchanged to the display values. Some image-recognition pipelines intentionally use display images; their training and validation must use the same processing path.

Nonlinear mappings such as histogram equalisation make the problem worse, because they change relative spacing between values as well as their scale. For quantitative work, take data before AGC and apply display mapping only to a copy.

Where the tap sits in each compared RAW thermal camera

  • Earlier FlexMini Y16 firmware documented separate RAW, pre-AGC and post-AGC taps. The V1.2.0 resources document a separate USB capture workflow.
  • ThermoCore 640: the USB SDK exposes AGC levels 0–5; level 0 disables AGC. Use the radiometric conversion that matches the selected USB mode.
  • AeroMini 640: obtain the RAW interface and SDK definition for the radiometric RAW profile, including which processing precedes the RAW output.

The FlexMini tap list carries a useful warning: tap 4 is post-AGC yet still described as 14-bit. A 14-bit word length therefore does not, by itself, prove that data is pre-AGC.

Mode labels are not portable commands

The configuration labels supplied with these profiles include a mode designation whose exact command mapping is not published for all three products. We do not translate it into a specific command here. When ordering, ask which control produces the compared RAW profile on the delivered firmware, and confirm it by reading back the active state.

NUC and FFC events in a RAW thermal camera stream

Every pixel of an uncooled microbolometer array has its own offset and gain. Non-uniformity correction (NUC) compensates for those differences so a uniform scene produces a uniform image. Because offsets drift as the camera’s internal temperature changes, the correction must be refreshed during operation. Many cameras do this with flat-field correction (FFC), often by briefly closing a shutter in front of the detector; shutterless designs use scene-based or model-based methods instead.

What an FFC event looks like in RAW data

Depending on the RAW thermal camera, frames during a correction can freeze, repeat, show the shutter surface or be flagged as invalid. After the event, the overall level or fixed pattern of the image can shift slightly. In display video the shift is often masked by AGC. In RAW thermal camera data it remains visible as a step in mean value or a change in noise texture.

For a tracker or a detection model, such a step can look like a scene change. For a radiometric recording, readings taken across the event may need to be marked or excluded according to the vendor’s guidance.

Recording practice around correction events

  • Log a timestamp and frame counter for every buffer, so pauses and repeats can be found later.
  • Record any correction status or telemetry flag the SDK exposes alongside the frame.
  • Where no flag is available, detect identical consecutive buffers and abrupt changes in the global mean as candidate events.
  • Ask whether correction can be triggered manually, scheduled, or only run automatically, and which choice the radiometric conversion expects.

Tap position and fixed-pattern noise

In FlexMini’s published tap order, NUC follows tap 0. Data taken at tap 0 is therefore positioned before that correction stage and can be expected to carry pixel-to-pixel non-uniformity that later stages are meant to remove. That can be exactly what a team building its own correction pipeline wants, and exactly what a team expecting a clean image does not. Select the tap deliberately.

Warm-up behaviour

After power-on, the camera body and detector move towards thermal equilibrium, and correction activity is often more frequent during that period. Record warm-up separately in any evaluation and do not use its first minutes to judge long-term stability. The CAMCUDA article on infrared ISP, NUC and thermal drift explains these interactions in more depth.

4. Define the frame before writing the decoder

Request a sample file and its complete layout: pixel format, dimensions, byte order, meaningful bit positions, row stride, headers, telemetry and any separate temperature plane. Do not copy a bit mask or shift from another camera. Incorrect alignment can produce a recognizable image while corrupting the numeric values.

On Linux, enumerate the delivered device’s formats and intervals before choosing a capture mode. A generic viewer can display a converted image without preserving the original words. Save an unchanged capture buffer for validation, and produce an independent scaled image for viewing. Keep the SDK, firmware identifier and format description beside each recorded dataset.

AeroMini’s 15 Hz figure here is specific to the compared radiometric RAW profile; its product page also lists 25 Hz radiometric imaging. Likewise, ThermoCore’s current listed formats are 25 Hz, while the RAW profile range is 25–30 Hz. The required board, firmware and capture mode must support the requested rate together.

Minimum frame description to request

  • Pixel format name and, on Linux, the enumerated format identifier.
  • Width, height and row stride in bytes.
  • Byte order of each word and the positions of meaningful bits.
  • Location and size of any header, footer or telemetry lines.
  • Whether a temperature plane or second data plane is sent, and its encoding.
  • The processing stage of the data and the control that selects it.
  • Firmware, SDK and board identifiers the description applies to.

Why a picture is not proof

Thermal scenes are forgiving to look at, which makes RAW thermal camera decoding errors easy to miss. A byte-swapped or shifted frame can still show recognisable shapes, especially after automatic scaling in a viewer. Validate numbers, not appearance: compare decoded values against the vendor’s sample tool output, or against the statistics a reference program prints for the same buffer.

How to collect, record and convert raw thermal data

Collecting raw thermal data is simple to start and easy to get subtly wrong. The rule that prevents most problems is to keep the exact bytes delivered by the RAW thermal camera, describe them completely, and generate every other representation from that archive.

Step 1: capture the delivered format

For the earlier Y16 workflow, Linux format enumeration and the capture example were configuration-specific. The current USB workflow is documented separately in the V1.2.0 user manual.

v4l2-ctl -d /dev/video0 --list-formats-ext

The following command was used with the earlier Y16 package.

./raw_y16_grab /dev/video0 frame_y16.raw 640 512 5 frame_y16.pgm 10

Use the README in the delivered package for argument meanings. For any other RAW thermal camera family, use the capture tools and SDK provided with that package.

Step 2: choose a recording format

FormatWhat it storesStrengthWatch for
Raw frame dumpThe exact buffer bytes, one or many framesNothing is lost or reinterpretedUseless without a sidecar describing size, stride, byte order and bit layout
16-bit PGMWidth, height, maximum value and samplesSimple header; readable by many toolsThe Netpbm format stores 16-bit samples most significant byte first; little-endian buffers must be swapped when written
16-bit TIFFTagged image with declared bit depth and byte orderWidely supported by scientific and imaging softwareCheck that the writer does not rescale or convert to 8-bit
Vendor radiometric containerImage data plus calibration and scene parameters, in a vendor format such as radiometric JPEG or sequence filesKeeps the information needed for later temperature re-analysisUsually requires the vendor’s SDK or software to read correctly
Compressed videoAn encoded display streamSmall files for reviewCommon pipelines are lossy and 8-bit; not a RAW archive

The official PGM format specification is worth reading before writing PGM files, because the byte order of 16-bit samples differs from the little-endian convention of standard V4L2 Y16.

Step 3: write a sidecar for every recording

Store a small text or JSON file beside each RAW thermal camera dataset with: module and version, board, firmware and SDK identifiers; pixel format, width, height, stride and byte order; meaningful bit positions; RAW tap or AGC setting; frame rate requested and observed; correction mode; and, for radiometric data, the scene parameters and conversion version. Without this, a recording becomes difficult to interpret within weeks.

Step 4: convert in a fixed order

  1. Read words with the documented byte order.
  2. Apply only the documented sample decoding, including a mask or shift if that format requires one.
  3. Reshape using width, height and stride; discard documented padding and telemetry.
  4. Check statistics against the reference tool for the same buffer.
  5. For viewing, scale a copy to 8-bit using your own percentiles or fixed limits.
  6. For temperature, apply the vendor’s conversion only to radiometric data from the matching configuration.

A short example of step 1–3 for a frame already confirmed to be unpacked, little-endian Y16 without headers might look like this in Python. Treat it as a template, not a definition of any vendor format:

import numpy as np
w, h = 640, 512
frame = np.fromfile("frame_y16.raw", dtype="<u2", count=w * h).reshape(h, w)
print(frame.min(), frame.max())

Converting raw data for review

Reviewers need images, not RAW thermal camera arrays. Generate them from the archive with a stated mapping—fixed limits for comparisons across a dataset, or percentile limits for individual inspection—and label them as display renderings. Never overwrite the raw thermal data with its rendered version.

5. Budget payload using the transmitted container width

For one 640 × 512 image plane stored at two bytes per pixel, the payload is 655,360 bytes per frame: 0.65536 MB or 0.625 MiB. Use two bytes for a 14-bit signal carried in a 16-bit container. Packed 14-bit data is a different layout.

Image payload per second = width × height × bytes per pixel × frames per second
RAW frame rateDecimal payloadBinary payloadCompared profile
15 Hz9.8304 MB/s9.375 MiB/sAeroMini radiometric RAW
25 Hz16.384 MB/s15.625 MiB/sThermoCore radiometric RAW
30 Hz19.6608 MB/s18.75 MiB/sThermoCore; confirm configuration
50 Hz32.768 MB/s31.25 MiB/sFlexMini non-radiometric RAW

These are calculated image payloads, not measured USB throughput. Transport headers, padding, metadata, extra planes and memory copies add traffic. Reserve headroom and measure sustained reception on the intended host. The RAW module selector and payload calculator makes the same assumptions visible alongside its results.

Frame rate vs data rate vs host bandwidth for a RAW thermal camera

“How fast is it?” has at least four answers for a RAW thermal camera, and specifications rarely say which one they mean. Keeping them apart avoids both over-buying and failed integrations.

Four different rates

  • Detector or camera rate: the rate a family or version is listed at in general product material.
  • RAW mode rate: the rate of the particular RAW thermal camera output profile on a given board and firmware. This is the rate compared in this guide.
  • Image payload rate: frame size multiplied by the RAW mode rate—a calculated figure.
  • Sustained host rate: what your application actually receives, processes and stores over hours, measured on your hardware.

The compared profiles show why the distinction matters. AeroMini’s product page lists a 25 Hz radiometric option while the compared radiometric RAW profile is 15 Hz. ThermoCore’s listed UVC formats are 25 Hz while its RAW profile range is 25–30 Hz, with 30 Hz conditional on configuration.

Calculated image payload for 640 × 512 RAW

At two bytes per pixel, one frame is 640 × 512 × 2 B = 655,360 B. That gives:

Frame rateBytes per framePayload (MB/s)Payload (MiB/s)
15 Hz655,3609.83049.375
25 Hz655,36016.38415.625
30 Hz655,36019.660818.75
50 Hz655,36032.76831.25

These figures are image payload only. They are not measured bus throughput and they exclude every form of overhead.

What sits between payload and bandwidth

Transport protocols add framing and headers. Some interfaces pad rows or insert telemetry. A radiometric configuration that sends a temperature plane in addition to the image plane adds that plane’s payload. On the host, each memory copy moves the full payload again, and recording, display conversion and inference each read the data at least once more. A RAW thermal camera design that looks comfortable at the payload level can still drop frames when these are added together.

Interface notes for the compared RAW thermal camera modules

  • USB UVC: FlexMini’s RAW path is USB UVC Y16, and ThermoCore’s listed configuration uses Type-C UVC. Confirm the enumerated format and frame interval on the delivered unit.
  • Parallel and MIPI outputs: the FlexMini RAW workflow compared here is USB UVC Y16 on the non-radiometric standard tailboard. The separately listed MIPI-only tailboard does not support RAW output. Its future RAW firmware is under development, with no confirmed release date; do not design around an assumed upgrade.
  • Network: a network option for the 26 mm ThermoCore core is available by enquiry. Treat its formats and rates as a separate configuration.

How to measure sustained throughput

Run the full RAW thermal camera application—capture, processing and storage—for a long period, not a short burst. Count received frames against elapsed time, check frame counters or timestamps for gaps and repeats, and watch CPU load and storage write rate. Repeat with other USB or network devices active, because shared controllers are a frequent cause of drops in embedded hosts.

Host integration and SDK checklist: Raspberry Pi, Jetson and embedded Linux

Most RAW thermal camera integrations fail on details rather than on headline specifications: a driver that converts frames silently, an SDK built for the wrong architecture, or a control channel nobody asked about. The checklist below is generic; apply it to the exact package delivered with your module.

Driver and format

A UVC RAW thermal camera on Linux is handled by the kernel’s USB video class driver, so the kernel must include it. Confirm that the device binds, that the RAW format appears in the format list and that the required frame interval is offered. Some high-level capture libraries convert frames to 8-bit or colour by default; disable that conversion or read buffers through V4L2 directly so the original words are preserved.

SDK delivery

  • Is the SDK supplied as source code, prebuilt libraries or both?
  • Which CPU architectures are supported—x86-64, 64-bit ARM, 32-bit ARM?
  • Can it be cross-compiled? The FlexMini test program accepts a cross-compilation toolchain prefix.
  • Does it depend on a particular kernel, C library or driver package?
  • Are control functions documented with their valid values and read-back calls?

For ThermoCore, the release package includes USB SDK documentation, host software and drivers; read the host-software README before changing a USB driver. FlexMini’s current package provides a serial command reference, host applications and a RAW reading example.

Raspberry Pi class hosts

Single-board computers handle a RAW thermal camera well when the whole path is planned. Check USB power budget for the RAW thermal camera module, avoid sharing the camera’s USB controller with high-traffic devices where possible, and measure storage write speed before committing to continuous recording. Keep conversion to display images out of the capture thread.

Jetson and GPU hosts

GPU-equipped hosts suit RAW thermal camera pipelines that feed detection or segmentation models. Plan where the 16-bit data is converted to the model’s input type, minimise copies between CPU and GPU memory, and keep an untouched copy of the RAW buffer if recordings are needed for later training or validation.

Custom embedded Linux

On Yocto or Buildroot images, enable the USB video class driver and V4L2 user-space tools, add device-permission rules so the application does not need root access, and create stable device names when more than one camera is attached. Lock the RAW thermal camera firmware, SDK and kernel versions that passed acceptance testing.

ItemWhy it mattersHow to verify
Format enumerationThe RAW format and interval must exist on the delivered firmwareList formats and intervals on the target host
Buffer integritySilent conversion destroys RAW valuesCompare a saved buffer with the vendor tool output
Control channelAGC, tap and correction controls may use a separate path from videoSet a control, then read back the effective state
Architecture supportPrebuilt SDKs may not cover the host CPUBuild and run the sample program on the target
Sustained ratePayload is not throughputLong-duration frame counting under full load
Version lockBehaviour can change with firmware or SDK updatesRecord identifiers with each dataset and release

6. Match the complete assembly to the host

AeroMini lists a 21 × 21 × 28 mm body and weight below 20 g, both excluding lens and flange, with typical module power below 0.7 W. ThermoCore offers 21 mm and 26 mm core cross-sections; its 26 mm reference is 26 × 26 × 37 mm and 30.0 g excluding lens, with 0.8 W typical power. Do not assign that length or weight to the 21 mm core.

FlexMini lists 23.1 g module mass, power below 0.7 W and a 5–24 V supply. These figures describe different assemblies and conditions, so they do not support a matched efficiency ranking. Include the interface board, lens, connector clearance and thermal path in the design.

RAW thermal camera integration reference: CAMCUDA FlexMini 640 rear assembly
FlexMini 640 product reference from the current CAMCUDA page. Select the actual lens and interface assembly for the project.

Power and supply

AeroMini lists a 5 V typical supply with the selected board’s pinout applying; ThermoCore lists DC 5 V; FlexMini lists 5–24 V. RAW thermal camera supply ranges belong to specific boards, so confirm them for the exact interface board ordered. Allow for start-up current and any correction mechanism when sizing a regulator.

Mechanics and thermal path

Body dimensions in the listings exclude the lens and, for AeroMini, the flange. Add lens length, connector and cable bend clearance, and mounting features. A RAW thermal camera is itself sensitive to its own temperature, so give it a stable mounting and keep hot electronics from heating the housing unevenly.

RAW thermal camera mechanical reference: CAMCUDA ThermoCore 640 dimensions drawing
ThermoCore 640 mechanical reference from the current CAMCUDA page. Use the drawing that matches the ordered 21 mm or 26 mm core.

Optics and windows

The lens determines field of view and working distance; it does not change the RAW format. If the RAW thermal camera sits behind a protective window, the window material and condition affect the received signal, and a radiometric configuration needs that influence accounted for in its settings.

RAW thermal camera module size reference: CAMCUDA AeroMini 640 with Type-C interface
AeroMini 640 product photo from the current CAMCUDA page, showing its Type-C interface. Confirm the board used for the radiometric RAW profile.

7. Agree the sample acceptance checks before ordering

Specify whether the host needs calibrated temperature, minimum RAW rate and required processing stage. Request the exact board and firmware, supported formats and a matching sample file. For thermography, also request conversion rules, calibration scope, measurement conditions and correction settings.

During evaluation, record timestamps and frame counts, check for dropped or repeated frames, and inspect startup, warm-up and shutter events. Validate numeric decoding before assessing contrast. Evaluate temperature performance separately using suitable references. These are proposed project checks, not a report of tests on these three modules.

A practical sample acceptance test plan for a RAW thermal camera

The plan below turns those principles into steps with clear evidence. Adapt the duration and criteria to the application; the order matters more than the exact numbers you choose.

StepWhat to checkEvidence to keep
1. DocumentsFormat description, SDK, firmware and board identifiers match the unitPackage versions and checksums
2. EnumerationRAW format and required interval appear on the target hostSaved format list output
3. DecodingDecoded values match the vendor reference tool for the same bufferRaw buffer, sidecar and statistics comparison
4. Processing stageChanging the AGC or tap control changes the data as documented, and the read-back confirms the effective stateHistograms before and after the change
5. Rate stabilitySustained frame rate over a long run with no unexplained gaps or repeatsFrame counter and timestamp log
6. Correction eventsBehaviour of frames around NUC or FFC events and during warm-upEvent log aligned with frame data
7. Temperature (radiometric only)Readings against suitable calibrated references within the listed range and conditionsReference setup, settings and results
8. IntegrationPower, mounting, thermal behaviour and cable routing in the real enclosurePhotos, supply measurements and notes

Write pass criteria before testing

Agree in advance what counts as acceptable RAW thermal camera behaviour for each step—how many dropped frames per hour, which decoding mismatch is tolerated (normally none), and which temperature references apply. Criteria written after seeing results tend to drift towards whatever the sample happened to do.

Keep the evaluation reproducible

Archive the RAW thermal camera recordings, sidecars and scripts used for each step. If a production lot later behaves differently, the same scripts can be rerun against new samples and the comparison is immediate.

Thermal camera module selection and price drivers

Buyers searching for a thermal camera module price usually find wide ranges with little explanation. Price follows from configuration choices, and the same choices decide whether a RAW thermal camera fits the host. We do not quote prices here; the drivers below explain what moves them.

What usually moves the price

  • Array size and pixel pitch: a 640 × 512 detector is a different class of component from small sensor arrays.
  • Radiometric calibration: temperature capability requires calibration work and documentation for each version.
  • Lens: infrared optics vary with focal length and aperture; longer focal lengths generally add cost.
  • Interface board: USB, parallel, MIPI or network boards differ in components and support effort.
  • Software and documentation: SDK access, host tools and integration support.
  • Quantity and customisation: sample, pilot and production volumes, plus any firmware or mechanical changes.
  • Compliance and logistics: destination-specific requirements, including export classification, which the supplier should confirm for each order.

For a broader breakdown, see CAMCUDA’s thermal imaging camera price breakdown.

Requirement-first RAW thermal camera selection

RequirementProfile to evaluateConfirm before ordering
Radiometric RAW at 15 HzAeroMini 640 radiometric RAWRAW interface and SDK definition; conversion method
Radiometric RAW around 25 HzThermoCore 640 radiometric USB RAWUSB SDK mode and packing; thermography option
Radiometric RAW at 30 HzThermoCore 640, conditionalExact board, firmware, format and interval for 30 Hz
Non-radiometric RAW at 50 HzFlexMini 640
14-bit RAW · Y16
Compatible serial switching and unchanged USB buffer capture
Radiometric RAW at 50 HzNo match among the compared profilesRevisit the requirement or discuss other configurations

Order of decisions

  1. Temperature or signal only.
  2. Minimum sustained RAW rate.
  3. Required processing stage and effective bit depth.
  4. Host platform and interface.
  5. Field of view, lens and mechanics.
  6. Volume, schedule and support.

The RAW thermal module selector follows the first two steps and estimates payload, then lets you copy a project brief for enquiries.

Maker-class sensor arrays vs 640 × 512 RAW thermal camera cores

Small infrared sensor arrays and 640 × 512 imaging cores solve different integration problems. A compact array can be useful for a zone-level thermal trigger; an imaging core provides more spatial samples for applications that need image structure. Compare the required task, optics, update rate and temperature capability alongside the published pixel counts.

Sensor classArrayTotal pixelsTypical role
Panasonic AMG88338 × 864Presence and coarse heat zones
Melexis MLX9064116 × 12192Low-resolution heat mapping
Melexis MLX9064032 × 24768Low-resolution thermal images for prototypes
640 × 512 LWIR core640 × 512327,680Imaging, detection at distance, image-based algorithms

What the pixel count changes

With the same field of view, more pixels mean each pixel covers a smaller part of the scene. Small or distant objects then occupy enough pixels to be detected, measured over an area rather than a single blurred spot, or classified by shape. An 8 × 8 array can support a coarse zone-level signal; a 640 × 512 core provides more samples for image-based analysis. Recognising an object still depends on its apparent size, optics, contrast and the validated algorithm, so array size alone establishes no recognition range.

When a small array is enough

Occupancy sensing, simple thermal triggers, education and early proof-of-concept work can be served well by small arrays, often with very simple host software. If the application only needs to know whether a zone is warmer than usual, a full imaging core may be unnecessary.

When to move to a 640 × 512 RAW thermal camera

Move up when the system must resolve shapes, track multiple objects, inspect fine detail or run image-based models. At that point the questions in this guide—radiometry, bit depth, processing stage, frame rate and payload—become the integration work, and a defined RAW profile saves time compared with reverse-engineering a display stream.

RAW thermal camera glossary

RAW
Numeric image output from a processing stage defined by the vendor. The exact tap determines which corrections and display mapping are included. RAW does not by itself mean temperature data or untouched detector output.
Radiometric
A camera configuration whose output, with matching calibration and conversion, can be expressed as temperature within a stated range and conditions.
Non-radiometric
A configuration that outputs signal or image values without a temperature calibration.
Y16
A single-channel format with one 16-bit word per pixel. Standard V4L2 Y16 is little-endian.
Effective bit depth
The number of meaningful sample bits; 14 bits give 16,384 levels.
Container width
The storage size used per pixel; a 16-bit container holds 65,536 codes but adds no precision to a 14-bit sample.
AGC
Automatic gain control: scene-adaptive mapping of signal values into a display range.
NUC
Non-uniformity correction: compensation for pixel-to-pixel offset and gain differences.
FFC
Flat-field correction: a periodic update of offset correction, often using a shutter as a uniform reference.
Tap point
The position in the processing chain from which a RAW thermal camera output is taken.
Stride
The number of bytes from the start of one row to the start of the next, which can exceed width × bytes per pixel.
Telemetry
Status data such as counters, temperatures or flags sent with or alongside RAW thermal camera frames.
UVC
USB Video Class, the standard that lets USB cameras work with generic operating-system drivers.
V4L2
Video4Linux2, the Linux kernel’s video capture interface and its user-space tools.
Image payload
Width × height × bytes per pixel × frame rate; a calculated figure excluding transport overhead.
LWIR
Long-wave infrared; the 8–14 μm band used by the compared modules.
Emissivity
How efficiently a surface emits thermal radiation compared with an ideal emitter; a key input to temperature conversion.

USB thermal camera integration: define the capture contract

A USB connector tells you how a cable attaches. It does not tell you whether the host receives an original grayscale plane, compressed display video, a temperature plane or several channels. When comparing a USB thermal camera with an OEM core, write down the exact stream and control path before choosing the host board. This avoids selecting a convenient connector and discovering later that the required data is available only on another assembly.

Keep the standard tailboard and optional boards distinct

For FlexMini 640, the documented RAW capture path is the non-radiometric standard-tailboard USB UVC Y16 configuration. The current product also lists separately selectable radiometric versions and a MIPI-only tailboard. Their presence in one configurator does not transfer RAW support between them: the MIPI-only board explicitly lacks RAW output, and the documented grayscale stream is not calibrated temperature data. Specify the camera version and tailboard together in the purchase configuration.

ThermoCore also has a mechanical and interface distinction. Its 21 × 21 mm option is a digital core, while the 26 × 26 mm Type-C configuration is the UVC USB reference discussed in this comparison. Network output for the larger core is a separate enquiry configuration. An unchanged detector does not make interface boards, cable definitions or host software interchangeable. Obtain the drawing and output description for the ordered assembly.

Separate transport controls from image controls

The video channel can work while a vendor control channel remains inaccessible to the application. During evaluation, confirm that the same host account can enumerate the requested format, open the capture stream, select the intended processing source and read its effective state. If an SDK requires additional permissions or libraries, document them in the deployment configuration instead of discovering the dependency after moving from an engineering workstation to an embedded image.

A stream restart can change the point at which a requested mode becomes active. Stop recording before changing a layout-sensitive setting, follow the matched SDK procedure, then re-read the actual format and source before starting a new recording. The Linux V4L2 buffer documentation explains why format and layout changes interact with allocated buffers. A successful control call is a configuration event, not evidence that an already queued frame uses the new layout.

Troubleshoot the numeric stream before adjusting the picture

A useful fault report names the failing layer. “The thermal image looks wrong” can describe an optical problem, a word-order mistake, an unsupported mode or an overloaded recorder. Use a short unchanged capture to separate those possibilities. The checks below are a diagnostic sequence for your evaluation; they do not describe faults observed on the three compared modules.

ObservationCheck firstEvidence to retain
Image appears, but saved values have only 256 levelsLook for an 8-bit conversion in the capture library or file writer. Recheck the format of the delivered buffer before changing camera settings.Enumerated format, bytes per frame and the untouched input buffer.
Repeated bands or broken row boundariesCompare row stride, header length, image height and any telemetry lines with the actual buffer layout. Do not force a reshape just because the file size is close.Buffer length, negotiated layout and a small byte-level excerpt.
Numeric values jump when the background changesRead back the active data source and determine whether scene-adaptive mapping is included. Compare both recordings using one fixed display scale.Source state, AGC configuration and the two original captures.
Recorder receives fewer frames under loadMeasure capture, processing and disk writing separately. A queue that grows continuously indicates the consumer cannot keep up, even if the live preview looks smooth.Elapsed time, frame counts, queue depth and storage timing.
Old recordings change after a software updateCheck decoder defaults, calibration inputs and library versions. Re-run the old decoder on the retained original bytes before attributing a difference to the camera.Original buffer checksum, old and new configuration, conversion version.

Make one change per comparison

Keep a baseline recording and change one setting at a time. If the firmware, source, decoder and display stretch all change together, a better-looking result gives little information about what improved. The same rule helps when moving from a maker sensor board or a processed-video camera: validate the delivered frame dimensions and sample meaning first, then bring in the existing display or analysis code.

Archive enough information to reproduce a result

Retain original buffers separately from derived files, and assign checksums so accidental modification can be detected. Record requested settings and effective settings as different fields. Keep the decoder version with the dataset, including any intentional normalisation, pixel replacement or temperature conversion. A later correction to that decoder should produce a new derived dataset while preserving the earlier result for comparison.

Store camera or driver timestamps together with a host-side monotonic arrival time where the capture API permits it. These clocks answer different questions and may not share an epoch. Do not subtract a camera timestamp from a host timestamp until their relationship is established. For a multi-camera system, define synchronisation separately from average frame rate; two cameras delivering the same number of frames per second are not automatically exposing each scene at the same instant.

RAW thermal camera FAQ

Does a 16-bit RAW thermal camera automatically measure temperature?

No. A 16-bit storage format does not establish temperature measurement. Select a radiometric camera configuration and use its matching calibration, conversion method and measurement settings. FlexMini 640’s compared 50 Hz RAW configuration is non-radiometric.

What is the difference between a radiometric and a non-radiometric thermal camera?

A radiometric configuration has calibration and a conversion method that allow its output to be expressed as temperature within a stated range and conditions. A non-radiometric configuration outputs signal or image values without that calibration. Either can be a RAW thermal camera; RAW describes the processing stage, not the measurement capability.

Is 14-bit data in a 16-bit container the same as native 16-bit data?

No. Fourteen data bits provide 16,384 possible levels. A 16-bit container can hold 65,536 codes, but placing a 14-bit sample in it adds no original signal precision. Confirm the actual data alignment and reserved bits before decoding.

Can non-radiometric RAW data be converted to temperature?

No calibrated temperature capability is established for the compared non-radiometric version. Relative signal analysis requires known polarity and processing. A project can develop its own characterisation, but that does not inherit the manufacturer’s radiometric range, conversion model or accuracy specification.

Which compared RAW profile provides 50 Hz?

One non-radiometric FlexMini test unit recorded 50.0 fps over USB on Windows. AeroMini’s compared radiometric RAW profile is 15 Hz. ThermoCore’s is 25–30 Hz, with the 30 Hz configuration requiring confirmation.

Why does AeroMini 640 show 25 Hz elsewhere but 15 Hz here?

The product page lists a 25 Hz radiometric camera option. This comparison refers specifically to the 15 Hz radiometric RAW output profile. A nominal camera rate and the rate of a particular RAW interface mode are separate specifications.

Does every ThermoCore 640 USB configuration support 30 Hz RAW?

No universal 30 Hz support is established. The listed product configuration is 25 Hz; the compared RAW range is 25–30 Hz. Confirm the board, firmware, pixel format and supported interval for the required 30 Hz configuration.

Are ThermoCore AGC level 0 and FlexMini RAW source 0 the same command?

ThermoCore documents AGC levels 0–5, with level 0 disabling AGC. The current FlexMini guide documents a separate serial mode switch. The controls are configuration-specific.

How much bandwidth does a 640 × 512 RAW thermal camera need?

One two-byte-per-pixel image plane contains 655,360 bytes. Its payload is 9.8304, 16.384, 19.6608 or 32.768 MB/s at 15, 25, 30 or 50 Hz respectively. These calculations exclude padding, metadata, additional planes and protocol overhead; they are not measured bus throughput.

How do I record and convert RAW thermal camera data?

Save the original buffers with a sidecar recording dimensions, stride, byte order, bit layout, processing stage and firmware. Decode using that documented layout, then verify numeric values against the matching reference tool. Keep display rendering and radiometric temperature conversion as separate outputs.

Why should AGC be disabled for RAW analysis?

For fixed signal thresholds or radiometric conversion defined before AGC, preserve the corresponding unmapped data. Scene-adaptive display mapping changes the numeric relationship as the view changes. Apply contrast mapping to a display copy; disabling AGC does not automatically bypass NUC or other corrections.

Can I use a RAW thermal camera with Raspberry Pi or Jetson?

Yes, if the delivered device exposes the required RAW format and the matching SDK supports the host architecture. Verify format enumeration, unchanged buffer capture, control access and sustained reception on the actual Raspberry Pi or Jetson before selecting the production configuration.

What should I send when requesting a RAW module configuration?

Specify whether the RAW thermal camera must measure temperature, the minimum RAW frame rate, effective bit depth, host operating system, interface, lens and assembly constraints. Request a sample capture, format and byte-layout details, matching SDK, conversion documentation and the exact board and firmware identifiers.

Technical sources and configuration notes

Configuration reference: 9 November 2026. The 15 Hz AeroMini and 25–30 Hz ThermoCore RAW profiles reflect current CAMCUDA configuration information. The linked manuals cover their published versions; the RAW profile updates do not replace those documents’ general imaging rates. Confirm the exact board, firmware and output mode for your project.

The payload figures are calculations from frame size and rate. No sample-file analysis, host benchmark or temperature-accuracy test of these three modules is reported in this article.

Cover: an editorial adaptation of a CC0 thermal photograph by Emilian Robert Vicol. It is an illustration, not a CAMCUDA product capture or quantitative measurement example.

Related reading: Y16 storage, RAW data, AGC, frame rate, infrared ISP corrections and data paths, the 14-bit RAW thermal camera module case: FlexMini 640 firmware and Y16 and how heat-sensing cameras work.

Build your RAW capture shortlist.

Choose the RAW thermal camera measurement requirement and minimum rate, estimate image payload, then send the selected profile with your host, optics and integration constraints.

Compare profiles in the selector →

Similar Posts