CAMCUDA / ENGINEERING TOOLS

Thermal RAW Module Selector

Choose the data your project needs. Compare AeroMini 640, ThermoCore 640 and FlexMini 640 by temperature measurement, RAW output rate and data format.

640 × 512

Three modules.
Different RAW workflows.

Radiometry · Rate · Data format

01 / YOUR REQUIREMENTS

Start with the output, then choose the module.

Every active filter must be met. A configuration that still needs confirmation appears separately from the candidate shortlist.

Enable JavaScript to filter the three models. The full comparison remains available below.

RAW rates below describe the selected data-output workflow. They are not interchangeable with a detector rate, processed video rate or measured host capture rate.

02 / IMAGE PAYLOAD

How much data will you capture?

Calculate a 640 × 512 image stream stored as two bytes per pixel. This is useful for a 16-bit container, including a 14-bit value carried in a 16-bit word.

At 25 frames/s, image payload is 16.384 MB/s. Ten minutes uses about 9.155 GiB before overhead.

Planning input: 1–120 frames/s. This calculator range does not establish a supported camera mode. Results exclude metadata, padding, transport overhead, file headers and compression. Confirm the selected host format before sizing a capture system.

03 / TAKE THE NEXT STEP

Carry the requirements into your enquiry.

Copy or download a project brief with the selected inputs, candidate models, remaining configuration checks and calculated image payload. Add your host, lens, temperature requirements and quantity before sending it to CAMCUDA.

Contact CAMCUDA →

THE THREE DATA PATHS

Thermal RAW module selector: compare the key specifications.

All three models use a 640 × 512 detector. The meaningful choice here is the delivered data path: whether it supports temperature measurement, which RAW formats are available and the rate for that selected mode.

Selection pointAeroMini 64060 Hz imagingThermoCore 640Radiometric USB RAWFlexMini 64014-bit RAW · Y16
Version comparedRadiometric RAW configurationRadiometric RAW configurationNon-radiometric RAW configuration
Detector resolution640 × 512640 × 512640 × 512
RAW data14-bit / 16-bit RAW options14-bit / 16-bit RAW options14-bit data carried in a 16-bit container
RAW output rate15 Hz25–30 Hz, configuration dependent50 Hz
Rate to use for an initial shortlist15 Hz25 Hz; confirm the 30 Hz configuration50 Hz
Temperature measurementRadiometric version; matching calibration and conversion requiredRadiometric version; matching calibration and conversion requiredNot provided by the non-radiometric version
Key integration checkRAW output mode and matching host capture pathExact rate, firmware, RAW mode and matching SDKValid-bit location, byte order and RAW processing stage

Keep the frame-rate labels attached to their modes.

AeroMini’s general radiometric imaging specification is 25 Hz; the radiometric RAW workflow compared here is 15 Hz. ThermoCore’s listed product configuration is 25 Hz, while its RAW selection range is 25–30 Hz depending on configuration. Select the exact module, firmware and output mode before treating an upper rate as an order specification.

CAMCUDA / PRODUCT FAMILIES

Explore the three module families.

Open the product pages for lens and interface configurations. These family reference images are not shown to scale and do not define the exact assembly for a selected RAW mode.

For the engineering background, read our RAW thermal camera module comparison covering radiometry, bit depth, processing stages and host capture.

READ THE RESULT CORRECTLY

How the thermal RAW module selector works.

01

Choose measurement or imaging.

If you need calibrated temperatures, start with a radiometric model. A high-bit-depth image from a non-radiometric model is still an imaging signal; the word size alone does not supply a temperature conversion or calibration. FlexMini therefore leaves the shortlist when temperature measurement is required.

02

Choose the RAW rate.

AeroMini enters a 15 Hz shortlist. ThermoCore enters a 25 Hz shortlist, and appears under configuration confirmation for a 30 Hz requirement. FlexMini supplies the listed 50 Hz imaging path. Asking for radiometry at 50 Hz produces no match in this three-model comparison.

03

Keep precision and packing separate.

The 14/16-bit option identifies the available RAW choices on the radiometric models. It does not prove native 16-bit detector accuracy. The 14-in-16 option directly matches FlexMini; a radiometric model needs confirmation of its selected 14-bit mode’s container and alignment.

The image-payload calculation

Bytes per frame = 640 × 512 × 2 = 655,360. Multiply by frames per second for bytes per second, then by recording time for image-only storage. Divide by 1,000,000 for MB/s, by 1,048,576 for MiB/s, or by 1,073,741,824 for GiB of storage.

For example, a 50-frame/s stream in a 16-bit container requires 32.768 MB/s of image payload. That number is a planning calculation, not a USB speed test. Line padding, telemetry, packet headers, file formats, disk behavior and capture software can change the actual resource requirement.

Use the command for the selected SDK.

ThermoCore’s product information identifies AGC level 0 as the setting that disables automatic gain control. FlexMini’s RAW source selector uses a different command field: source 0 identifies the RAW tap. These numbers are not a universal command shared across camera families. Confirm the matching SDK, source selection and gain-control setting for the chosen output path.

What the brief should settle

Specify the exact connector and interface board, camera firmware, host operating system and requested format. Ask where the stream is taken from the processing pipeline, whether correction remains active, how valid bits are aligned and which byte order is used. Obtain a representative capture and its matching format description before fixing the decoder.

For temperature measurement, also confirm the selected temperature range, conversion method, calibration conditions and required accuracy. Keep the recorded numeric data separate from the display image so contrast adjustments do not silently replace the values needed by your analysis.

The Linux V4L2 luma-format documentation explicitly distinguishes a Y16 storage format from the effective sampling precision. It is a useful format reference; the matching CAMCUDA SDK and capture sample determine the actual module layout.

Product references

AeroMini 640 configurations · ThermoCore 640 RAW & SDK · FlexMini 640 RAW integration · FlexMini 640 user manual · Documentation library

Configuration scope: 4 November 2026. Product pages carry current lens, interface and purchasing options. Confirm your selected RAW mode in the project quotation.

Thermal RAW module selector FAQ

Which module can I shortlist for radiometric RAW output at 15 Hz?

AeroMini 640’s radiometric RAW configuration is listed at 15 Hz. ThermoCore 640 also meets a minimum 15 Hz requirement with its listed 25 Hz configuration. Confirm the requested data format, output mode and temperature conversion for the selected module.

Does ThermoCore 640 always deliver 30 Hz RAW output?

No. Its RAW selection range is 25–30 Hz depending on configuration, and the listed product configuration is 25 Hz. The tool treats a 30 Hz requirement as a configuration check, rather than an unconditional match.

Is FlexMini 640 a radiometric 16-bit camera?

The compared FlexMini 640 version is non-radiometric. It carries 14-bit image data in a 16-bit container at 50 Hz. That transport format does not establish 16-bit native precision or calibrated temperature measurement.

Why does a 14-bit sample sometimes use two bytes?

A host format may store each sample in a 16-bit word for byte alignment. Fourteen valid bits still fit inside that word. Confirm the valid-bit location and byte order; do not assume a generic mask or shift from the word size alone.

Does the payload calculator include USB overhead?

No. It calculates only 640 × 512 image samples at two bytes per pixel. Metadata, padding, packet overhead, file headers and other traffic are excluded. Use a representative host capture to measure the complete system requirement.

Can I share the same selector inputs with my integration team?

Yes. Copy the selection link to preserve the chosen inputs. Copy or download the project brief to include the candidate models, conditional checks and image-payload calculation. Add the host, lens, measurement requirements and quantity before requesting a configuration review.