CAMCUDA ThermoCore 640 14/16-bit RAW USB Radiometric Thermal Camera Module
640 × 512 radiometric LWIR module with Type-C UVC USB, 25 Hz imaging, 14-bit / 16-bit USB RAW output and SDK AGC control.
Choose a 21 × 21 mm or 26 × 26 mm core and its compatible lens. Both sizes use the same detector and imaging design. Network-output configurations are available for the 26 mm core by enquiry.
1 / 2Price range: $1,250.00 through $1,550.00Inquiry-only lens options: Request a quote
Configure and purchase
Choose your configuration
Review the current online unit price, then check out or request an OEM quotation.
Confirming configuration…
Radiometric · 25 Hz · −20°C to +150°C.
Express checkout
OEM & volume pricing
Configuration review for custom projects and production orders.
Pricing is confirmed for your selected configuration.
Discuss a custom configurationTECHNICAL RESOURCES
Product documents
The downloadable datasheet and mechanical drawing describe the 26 × 26 mm reference core.
Description
THERMOCORE 640 · RADIOMETRIC USB
Thermal data.
Under your control.
A 640 × 512 LWIR thermal camera module for OEM systems that need temperature measurement, USB RAW output and SDK control of automatic gain.
- 640 × 512
- VOx · 12 μm
- 25 Hz
- Radiometric imaging
- 14 / 16-bit
- USB RAW output
- −20 to 150°C
- Temperature range
TWO CORE SIZES
One detector. Two integration formats.
Both sizes use the same detector and imaging design. With the same 9.1 mm lens, the difference is the core size: 21 × 21 mm or 26 × 26 mm.
21 × 21 mm
Digital core for compact integration.
| Lens | FOV (H × V) | Unit price (USD) |
|---|---|---|
| 4.6 mm | 104.5° × 80.7° | Request quoteEnquire about availability |
| 9.1 mm | 46.2° × 37.7° | $1,250Enquire about availability |
| 15 mm | 28.7° × 23.2° | Request quoteEnquire about availability |
| 19 mm | 22.9° × 18.4° | Request quoteEnquire about availability |
26 × 26 mm
UVC USB core, with network-output configurations available by enquiry.
| Lens | FOV (H × V) | Unit price (USD) |
|---|---|---|
| 9.1 mm | 46.2° × 37.7° | $1,250In stock |
| 15 mm | 28.7° × 23.2° | Request quoteEnquire about availability |
| 19 mm | 22.9° × 18.4° | Request quoteEnquire about availability |
| 25 mm | 17.5° × 14.0° | $1,250In stock |
| 35 mm | 12.5° × 10.0° | $1,350Made to order · 35 working days |
| 50 mm | 8.9° × 7.0° | $1,550In stock |
Prices apply to the Type-C USB configuration. Shared focal lengths use the same unit price across both sizes. Network-output configurations are quoted separately.
USB DATA & SDK CONTROL
Capture RAW. Set the gain.
14-bit or 16-bit USB output
The supplier confirms original 14-bit or 16-bit RAW output over USB for the 25 Hz radiometric module. Select the matching SDK mode for your host-side capture and processing workflow.
AGC levels 0–5
The supplier’s SDK provides AGC level adjustment from 0 to 5. Set the level to 0 to disable automatic gain control.
Prepare your Linux integration.
Request a sample RAW file, the Linux capture-format list and matching SDK. Include your host platform and required bit depth.
TECHNICAL REFERENCE
Specifications at a glance.
| Detector | |
|---|---|
| Detector type | Uncooled vanadium oxide (VOx) focal-plane array |
| Thermal resolution | 640 × 512 pixels |
| Pixel pitch | 12 μm |
| Spectral response | 8–14 μm |
| NETD | ≤40 mK at 25°C |
| Detector package | Ceramic |
| Optics & temperature | |
| Lens | 21 × 21 mm: 4.6 / 9.1 / 15 / 19 mm. 26 × 26 mm: 9.1 / 15 / 19 / 25 / 35 / 50 mm. |
| 35 mm field of view | 12.5° horizontal × 10.0° vertical · 26 × 26 mm core. See the size-specific lens tables for all fields of view. |
| Camera version offered here | Radiometric · 25 Hz |
| Temperature range | −20°C to +150°C |
| Temperature display | Full-screen maximum and minimum location; center temperature |
| Video & control | |
| USB video interface | UVC |
| USB RAW output | 14-bit or 16-bit RAW; supplier-confirmed |
| AGC control | SDK levels 0–5; level 0 disables AGC, as confirmed by the supplier |
| Listed MJEG modes | 640 × 512 at 25 fps; 1280 × 720 at 25 fps |
| Listed YUV2 modes | 640 × 512, 640 × 514 or 640 × 1026 at 25 fps |
| Communication | UART |
| Image processing | Non-uniformity correction, intelligent gain control, digital detail enhancement, 3D noise reduction |
| Palettes | 10 palettes, including black hot, white hot, iron red and rainbow; customization available |
| Image mirroring | Horizontal, vertical and center |
| OSD menu | Supported |
| Startup time | 10 seconds |
| Power & mechanics | |
| Input voltage | DC 5 V |
| Typical power consumption | 0.8 W |
| Hardware connector | Type-C USB for the configurations listed here. |
| Core dimensions | 21 × 21 mm or 26 × 26 mm cross-section. The 26 mm reference core is 26 × 26 × 37 mm, excluding lens. |
| Core weight | 26 × 26 mm reference core: 30.0 g, excluding lens. |
| Environment | |
| Operating temperature | −30°C to +60°C |
| Storage temperature | −45°C to +75°C |
| Humidity | ≤95% RH |
USB RAW and AGC settings are supplier-confirmed. The video mode names MJEG and YUV2 are retained from the manual; the exact Linux pixel formats and RAW packing require the matched SDK documentation.
HARDWARE INTEGRATION
Choose the connection.
Plan the assembly.
21 × 21 mm digital core
A compact format using the same detector and imaging design as the 26 mm core. Choose from 4.6, 9.1, 15 or 19 mm optics. This size is offered as a digital core only.
26 × 26 mm USB or network
The larger core supports 9.1, 15, 19, 25, 35 and 50 mm lenses, including larger optics. Type-C UVC USB is the configuration selected on this page.
For a network-output core, request the network configuration.

OEM APPLICATIONS
Built into your system.
Embedded thermal vision
Integrate into handheld devices, night-vision equipment and compact UAV platforms, with optics and host capture matched to the application.
Temperature-aware devices
Evaluate thermal observation and temperature display for fire-helmet and other OEM device projects. System-level suitability is determined by the complete integration.
QUESTIONS BEFORE INTEGRATION
ThermoCore 640 FAQ.
Can this 25 Hz radiometric module output 14-bit or 16-bit RAW data over USB?
Yes. The supplier confirms USB output of original 14-bit or 16-bit RAW data for this module. Request the matched SDK, sample capture and pixel-packing information for your selected configuration.
Can automatic gain control be disabled?
Yes. The supplier specifies SDK AGC levels from 0 to 5. Setting the AGC level to 0 disables automatic gain control.
Can I download a RAW sample file and Linux format list?
Use the SDK & sample data enquiry below to request these from CAMCUDA. A RAW sample file and verified Linux capture-format list have not been supplied for download. Share your Linux distribution, host hardware and required RAW bit depth.
What image formats and resolutions are listed?
The datasheet lists MJEG at 640 × 512 or 1280 × 720, and YUV2 at 640 × 512, 640 × 514 or 640 × 1026, all at 25 fps. These are the manual’s labels; request the exact Linux/V4L2 FourCC, packing, byte order and SDK mode mapping for your application.
Does a 16-bit RAW value directly represent a temperature?
Not necessarily. RAW pixel output and converted temperature values are different data products. Use the matched radiometric SDK and its conversion instructions for temperature processing.
Which temperature functions are included in this listing?
This listing is for the radiometric version. The specified measurement range is −20°C to +150°C, with full-screen maximum and minimum temperature location and a center temperature display. Measurement accuracy is not specified in the supplied datasheet.
Which USB connector is supplied?
The configurations listed here use Type-C USB. The 26 × 26 mm model can also be supplied as a network-output core by enquiry; that is a separate configuration. The 21 × 21 mm model is a digital core only.
What is supplied with the module?
One radiometric ThermoCore 640 module with the selected core size, lens and a Type-C USB connector. Confirm any required cables, adapters or enclosure with CAMCUDA.
Which lens configurations are available?
The 21 × 21 mm core supports 4.6, 9.1, 15 and 19 mm lenses. The 26 × 26 mm core supports 9.1, 15, 19, 25, 35 and 50 mm lenses. Select the core size first to see its compatible optics. Existing 26 mm core prices are unchanged; shared focal lengths use the same price for the 21 mm core.
Is this the same module as AeroMini 640?
No. ThermoCore 640 is a separate module with its own detector, dimensions, interfaces and radiometric configuration. The USB RAW output and AGC statements on this page do not change the specifications or availability of AeroMini 640.
What should I include in an integration enquiry?
Send the core size, lens, output interface, required RAW bit depth, host hardware, operating system and quantity. For network output, specify the 26 × 26 mm core and ask for its matched integration documentation.
What is the lead time for the 35 mm configuration?
The 26 × 26 mm core with a 35 mm lens is made to order with a lead time of 35 working days. The 26 mm core with 9.1, 25 or 50 mm optics is in stock. Availability and lead times for newly added configurations are confirmed by enquiry.
How do the 21 mm and 26 mm cores differ?
They use the same detector and imaging design. With the same 9.1 mm lens, the distinction is the 21 × 21 mm versus 26 × 26 mm core size. The 26 mm core also accommodates larger lenses and can be configured for network output. The 21 mm core supports digital output and the four smaller lenses listed above.
FROM EVALUATION TO INTEGRATION
Define your thermal data path.
Review the module configuration, request the SDK and confirm the host-side capture workflow with our team.
Additional information
| Weight | 0.5 kg |
|---|---|
| Core size | 26 × 26 mm, 21 × 21 mm |
| Lens focal length | 4.6 mm, 9.1 mm, 15 mm, 19 mm, 25 mm, 35 mm, 50 mm |
| USB connector | Type-C |
| Camera version | Radiometric · 25 Hz |
| Thermal resolution | 640 × 512 |
| Pixel pitch | 12 μm |
| Spectral range | 8–14 μm |
| Temperature range | −20°C to +150°C |
| USB RAW output | 14-bit / 16-bit (supplier-confirmed) |
| AGC control | SDK levels 0–5; 0 = off |
| Core dimensions | 21 × 21 mm or 26 × 26 mm cross-section; 26 mm reference core depth 37 mm, excluding lens |
| Core weight | 26 × 26 mm reference core: 30.0 g, excluding lens |